One of the frequent causes of non-traumatic lower-limb amputation is Diabetes and is usually preceded by foot ulcer and infection. The reason of this ulceration is commonly a loss of protective sensation due to peripheral neuropathy, for which there is no prevention strategy. Current research promotes early detection of neuropathy so that secondary prevention measures, such as intensive foot-care education and treatment, can be used for individuals.
Since diabetic neuropathy involves the nerves, the neurological exam is a crucial part of the diagnosis. Different nerves are in charge of transmitting different sensory messages, such as temperature, touch, and vibration. Damaged nerves can’t transmit messages as well as they should, so these tests can be very helpful in narrowing down which nerves are affected.
Approx. Rs 40,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Application Area | Multiple sites |
| Frequency | 50 Hz |
| Model Name/No. | Vibrometer |
| Vibration Range | 0–50 V |
| Display Type | LED |
| Power Source | Mains |
| Intended Use | Testing sensory threshold, Examining early symptom of diabetic foot, Peripheral nerve system testing, Nerve regeneration research, Sexual dysfunction inspection, Diabetic foot disease test, High risk foot diease screening |
| Brand | DFCIndia |
| Test Method | Electronic Tuning Fork |
| Power Supply | 230 V |
| Weight | 3 Kg |
| Probe Type | Handheld probe |
| Usage | Clinic, Hospital |
| Power Input | 30 W |
| Brand Origin | Indian |
| Country of Origin | Made in India |
| Operation Mode | Digital |
| Type | USB Connectivity |
Vibration Perception Threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Vibrometer Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing.
Sensory neuropathy increases the risk of foot ulcerations by seven folds and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factors in the development of foot ulcerations among diabetic subjects.
Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes who is a high risk group.
We are the first to introduce the Digital Biothesiometer in the Indian market as early as January 2004.
Additional Information:
Approx. Rs 1,50,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Test Type | VPT + HCP |
| Type | USB Connectivity |
| Display Type | LED Display |
| Application | Clinical |
| Channels | 2 channels |
| Connectivity | PC + Standalone |
| Power Source | Mains |
| Power Supply | 230 V |
| Intended Use | High risk foot diease screening, Sexual dysfunction inspection, Testing sensory threshold, Nerve regeneration research, Peripheral nerve system testing, Examining early symptom of diabetic foot, Diabetic foot disease test |
| Test Method | Hot,Cold,Vibration and Touch |
| Weight | 3 Kg |
| Power Input | 30 W |
| Usage | Clinic Use, Hospital Use |
| Frequency | 50 Hz |
| Body Material | ABS + Metal |
| Report Format | Paper + PDF |
| Country of Origin | Made in India |
| Temperature Output Range | 1-50degC |
| Temperature Range | 1degree C per sec |
| Vibration | 0 to 50 Volts |
| Touch | Fixed 10gm |
| Reportering | Software helps to get color reports through Comput |
| Computer Connectivity | Through USB cable |
Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988).
Small-fiber Test provides an easy-to-use and scientifically validated measure of warm, cool and heat pain thermal sensory thresholds, all clinically useful determinants in the evaluation of diabetic neuropathy.
Vibration Perception Threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of foot. Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing.
Sensory neuropathy increases the risk of foot ulcerations by seven folds and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factors in the development of foot ulcerations among diabetic subjects.
Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes who is a high risk group
This model is a Proprietary item and solely manufactured by us in India.
Additional Information:
Approx. Rs 40,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Operation Mode | Digital |
| Frequency | 50 Hz |
| Application Area | Multiple sites |
| Model Name/Number | Vibrotest Lx |
| Intended Use | High risk foot diease screening |
| Brand | DFCIndia |
| Type | Fully Automatic |
| Vibration Range | 0–50 V |
| Display Type | LED |
| Power Source | Mains |
| Tests Performed | Test are done on the sole of the foot |
| Standard Tests | Vibration Perception Threshold |
| Accuracy | +/- 5% |
| Weight | 3 Kg |
| Method | Electronic Tuning Fork |
| Probe Type | Handheld probe |
| Usage | Hospital |
| Power Input | 30 W |
| Brand Origin | Indian |
| Eeg Acquisition Software For Os Android | Windows and Android Software |
| Power Supply | 230 Volts |
| Country of Origin | Made in India |
Additional Information:
Approx. Rs 40,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Frequency | 50 Hz |
| Application Area | Multiple sites |
| Model Name/No. | Vibrotest |
| Intended Use | High risk foot diease screening |
| Vibration Range | 0–50 V |
| Display Type | LED |
| Power Source | Mains |
| Brand | DFCIndia |
| Test Method | Automatic |
| Weight | 2.5 Kg |
| Accuracy | +/- 2% |
| Method | To detect the loss of vibration sense for grading neuropathy. |
| Probe Type | Handheld probe |
| Number Of Signal Input Channels | One |
| Power Supply | 230 V |
| Usage | Hospital, Clinic |
| Power Input | 30 W |
| Brand Origin | Indian |
| Alarm System | Available |
| Operational Time | Continuous |
| Country of Origin | Made in India |
| Operation Mode | Digital |
| Type | USB Connectivity |
Additional Information:
Approx. Rs 40,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Operation Mode | Digital |
| Application Area | Multiple sites |
| Model Name/No. | Vibrotest Lx |
| Vibration Range | 0–50 V |
| Display Type | LED |
| Power Source | Mains |
| Usage/Application | Bedside Testing |
| Type | Portable, USB Connectivity, Bench-top, Digital |
| Intended Use | Diabetic foot disease test, High risk foot diease screening, High risk foot diease screening,Sexual dysfunction inspection,Examining early symptom of diabetic foot,Peripheral nerve system testing,Testing sensory threshold,Nerve regeneration research,Diabetic foot disease test, Examining early symptom of diabetic foot |
| Brand | DFCIndia |
| Test Method | Automatic and manual |
| Weight | 3 Kg |
| Power Supply | 230 V |
| Method | Electronic Tuning Fork |
| Probe Type | Handheld probe |
| Usage | Clinic, Hospital |
| Power Input | 30 W |
| Brand Origin | Indian |
| Country of Origin | Made in India |
| Dimensions | 30 cm x 12 cm x 26 cm |
| Frequency | 50 Hz |
Additional Information:
Approx. Rs 85,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Test Type | Hot and Cold HCP |
| Type | Vibration threshold tester |
| Display Type | LED Display |
| Application | Bedside Testing, Hospital, Clinical |
| Channels | 1 channel |
| Connectivity | PC + Standalone |
| Power Source | Mains |
| Intended Use | High risk foot diease screening, Peripheral nerve system testing, Diabetic foot disease test, Testing sensory threshold, Sexual dysfunction inspection, Nerve regeneration research, Examining early symptom of diabetic foot |
| Power Supply | 230 V |
| Brand | Vibrotherm |
| Power Input | 30 W |
| Usage | Hospital Use, Clinic Use |
| Frequency | 50 Hz |
| Body Material | ABS + Metal |
| Report Format | Paper + PDF |
| Model Name/Number | Vibrotherm Dx |
| Usage/Application | Clinical Purpose |
| Process | Detects the loss of Thermal Sense (Hot/Cold), Vibration Sense and Touch Sense. |
| Country of Origin | Made in India |
Failure to perceive variances in temperature in the extremities is the most decisive early symptom of distal symmetric polyneuropathy, a typical ailment accompanying diabetes mellitus (Ziegler 1988).
Small-fiber Test provides an easy-to-use and scientifically validated measure of warm, cool and heat pain thermal sensory thresholds, all clinically useful determinants in the evaluation of diabetic neuropathy.
Sensory neuropathy increases the risk of foot ulcerations by seven folds and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factors in the development of foot ulcerations among diabetic subjects.
Early detection helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes who is a high risk group.
Additional Information:
Approx. Rs 40,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Application Area | Multiple sites |
| Frequency | 50 Hz |
| Vibration Range | 0–50 V |
| Display Type | LED |
| Power Source | Mains |
| Intended Use | Testing sensory threshold, Nerve regeneration research, High risk foot diease screening, Sexual dysfunction inspection, Examining early symptom of diabetic foot, Diabetic foot disease test, Peripheral nerve system testing |
| Test Method | Electronic Tuning Fork |
| Power Supply | 230 V |
| Weight | 3 Kg |
| Probe Type | Handheld probe |
| Usage | Clinic, Hospital, Diagnostic lab |
| Power Input | 30 W |
| Brand Origin | Indian |
| Brand | DFCIndia |
| Application | Hospital, Clinical, Bedside Testing |
| Country of Origin | Made in India |
| Operation Mode | Digital |
| Type | USB Connectivity |
Vibration perception threshold (VPT) has been shown to be strongly associated with foot ulceration. VPT determination by using a Digital Biothesiometer has been used to identify peripheral sensory neuropathy and subjects at risk of foot. Vibrotest Digital Biothesiometer helps us quantitate the threshold and monitor progressive changes or trends on following up testing.
Sensory neuropathy increases the risk of foot ulcerations by seven folds and peripheral arterial disease (PAD) by three folds in people with diabetes. Peripheral neuropathy is the major causal factors in the development of foot ulcerations among diabetic subjects.
Early detection of vibration perception threshold (VPT) helps better prevention. Prevention is better than no cure. 50% of all non-traumatic amputations occur in diabetes who is a high risk group.
Additional Information:
Approx. Rs 1,60,000 / PieceGet Latest Price
Product BrochureProduct Details:| Minimum Order Quantity | 1 Piece |
| Test Type | CAN |
| Type | USB Connectivity |
| Frequency | 50 Hz |
| Display Type | PC Screen Only |
| Channels | 1 channel |
| Connectivity | PC Based |
| Power Source | Mains |
| Power Supply | 230 V |
| Intended Use | Nerve regeneration research, Cardiac Autonomic Tester |
| Weight | 3 Kg |
| Brand | DFCIndia |
| Power Input | 30 W |
| Usage | Clinic Use, Hospital Use |
| Body Material | ABS + Metal |
| Report Format | Paper + PDF |
| Model Name/Number | CANS504 |
| Country of Origin | Made in India |
| Application | Hospital |
| Usage/Application | Clinical Purpose |
Cans 504 Cardiac Autonomic Neuropathy System Analyser is a serious and common complication of diabetes. In randomly selected cohorts of asymptomatic individuals with diabetes, about 20% had abnormal cardiovascular autonomic function. Reduced heart rate variation is the earliest indicator of cardiovascular autonomic neuropathy. The increased prevalence of painless myocardial infarction in diabetes has been attributed to autonomic neuropathy. Damage to autonomic nerve fibres from the myocardium of patients dying from painless myocardial infarction has recently been reported.
It has been recommended that testing of diabetic individuals for cardiovascular autonomic dysfunction should be part of their standard of care. Noninvasive tests are suitable for routine screening for autonomic dysfunction or for monitoring the progress of autonomic neuropathy. When performed in a carefully controlled manner, the following tests have been validated and shown to be reliable and reproducible:
Additional Information:
Explore More Products
© Diabetik Foot Care India Pvt Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited