Vascular Doppler Recorder Products

A Closer Look At Non-Invasive Testing Methods For PAD

Whenever one suspects Peripheral Arterial Disease (PAD), the clinician must perform  the five non-invasive vascular testing methods that are commercially available and widely implemented. They include the ankle brachial index ABI), the toe-brachial index(TBI), pulse volume recording(PVR), transcutaneous oxygen monitoring(TCPO2) and skin perfusion pressure(SPP).

Ankle Brachial Index:

The ankle brachial index is the most well-known, non-invasive vascular testing tool. ABI test is performed with a Doppler and a blood pressure cuff. One calculates the ABI by dividing the ankle pressure by the brachial systolic pressure. An ABI of <0.9 is abnormal and  ABI values have a linear correlation with wound healing potential in lower extremity wounds.   Patients with DM may have calcified and hardened lower extremity arterial walls that cannot be readily compressed and occluded with blood pressure cuffs. This produces falsely elevated ankle pressure readings that are often in the “normal ABI range” (0.9 to 1.2) or sometimes in the non-physiological range of above 1.3. 
 
Pros.: The ABI is a relatively quick and cost-effective test for screening of PAD with known sensitivity and specificity of 90 percent or higher.  

Cons.: Calcified leg arteries in DM or dialysis patients may yield falsely elevated ABI results.  

Toe-Brachial Index:


One would calculate TBI by dividing the blood pressure of the great toe by the systolic brachial blood pressure. Toe pressure of > 50mmHg is considered normal. Toe pressure < 30 mmHg is considered severely ischemic.

Pros.:
 The digital arteries in great toes are considered to be less affected by medial arterial calcification.

Cons.: There are site limitations such as the inability to measure toe pressure due to toe wounds or toe amputation.

Vascular Doppler Recorder for ABI / TBI

REQUEST CALLBACK

Vascular Doppler Recorder for ABI / TBI
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
ApplicationHospital, Clinical
BrandVERSALAB
Frequency(MHz)5, 8
Waveform ModeSpectrum
Speaker Output(mW)300

Vascular Doppler Reocrder model VERSALAB LE is a semi automated vascular Doppler for measuring ABI and TBI.

We are pleased to offer ABI /TBI Arterial Doppler Recorder from our impressive collection of Vascular Doppler Recorder Products. It incorporates PC software for storage and printouts. It has wide ranging applications such as penile study, PPG study, manual ankle brachial study, and so forth. It is manufactured under rigid norms of quality and offered at leading industry prices.

Features:

Easy to operate Doppler with 8 MHz probe
PC software for storage and printouts
ABI & TBI measurement
Photoplethysmography (PPG) for Toe Pressure measurement
Semi-automated model
Doppler Velocity waveform
LCD Monitor

Specifications:

Dimensions (H,W,L) : 295 x 320 x 175mm
Doppler Probe: 8MHz Unidirectional
Doppler Shift Frequency: 50Hz to 5KHz
Photoelectric PPG Sensor
Operates in Mains Supply
Runs on Windows Xp, Windows 7,  Windows 8 & Windows 10 Computer 



Additional Information:

  • Item Code: Versalab-LE
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Chennai, India
  • Production Capacity: 100 per month
  • Delivery Time: Immediate
  • Packaging Details: As per customer requirement
Send Business Enquiry

View PDF

Automated Vascular Doppler Recorder for ABI / TBI

REQUEST CALLBACK

Automated Vascular Doppler Recorder for ABI / TBI
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
ApplicationHospital, Clinical
BrandVERSALAB
Frequency(MHz)5, 8
Waveform ModeSpectrum
Speaker Output(mW)300

Ankle Brachial Index Measuring System Automated ABI / TBI Vascular Ultrasound Doppler Recorder model VERSALAB Auto is an PC Windows based automated ABI, TBI, PVR, Segmental BP measuring system with interpretation. This is also capable of mesurning Penile Brachial Index for impotence study. Upper extrimity vascular and Carotid vascular study are also possible with this model. Measurement of venous disorders is an added feature of this model.

It is reckoned as the first indigenous Doppler facilitating BP measurement. It inflates BP cuffs noiselessly with silent pump and measures systolic BP of the extremities. It is provided with separate mode for a complete vascular profile study and also offers segmental cuff-sets wit manometer for ankle brachial index.

Features:

  • Portable and lightweight design
  • Large display
  • Computer Compatible
  • Supports Windows Xp, Vista, 7 and 8 platforms
  • Connectivity through USB port
  • Doppler/PPG waveform and blood pressure measurements are automated
  • India's largest selling vascular Doppler system


Additional Information:

  • Item Code: VERSALAB-Auto
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Chennai, India
  • Production Capacity: 100 per month
  • Delivery Time: Immediate
  • Packaging Details: As per customer requirement
Send Business Enquiry

View PDF

TBI Arterial Doppler Recorder

REQUEST CALLBACK

TBI Arterial Doppler Recorder
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
ApplicationHospital, Clinical
BrandVERSALAB
Frequency(MHz)5, 8
Waveform ModeSpectrum
Speaker Output(mW)300

We are engaged in supplying TBI Arterial Doppler Recorder from our premium collection of Vascular Doppler Recorder Products. It is designed for manual toe brachial index study and PPG for toe pressure measurement. It also facilitates penile flow study and monitoring and recording of velocity as well as pulse volume waveforms. It is provided with PC software for storing and printing of data and can be availed at competitive rates.

Features:

  • 8 MHz unidirectional doppler transducer
  • Manual ankle brachial index study
  • Photo plethysmography (PPG) for toe pressure measurement
  • Monitoring & Recording of velocity & pulse volume waveforms
  • Segmental cuffsets with Toe cuff for AB Index and TB Index
  • Penile flow study
  • PC software for storage and printout on A4 size plain paper
  • Gets connected on to any computer(computer not included) through RS232 serial port
  • USB Port connection is an option
  • Light weight and portable

Other Information:

  • Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer)
  • Minimum Order Quantity: 1 Piece/Pieces
  • Port of Dispatch: Chennai, India
  • Production Capacity: 100 per month
  • Delivery Time: Immediate
  • Packaging Details: As per customer requirement


    Additional Information:

    • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
    • Port of Dispatch: Chennai, INDIA
    • Production Capacity: 250 units per month
    • Delivery Time: Immediate
    • Packaging Details: As per Customer Requirement
    Send Business Enquiry

    View PDF

    PC Based Vascular Doppler Recorder

    REQUEST CALLBACK

    PC Based Vascular Doppler Recorder
    Ask for Price

    Thanks for Contacting Us.

    Product Price :Get Latest Price

    Product Details:
    Minimum Order Quantity1 Unit
    Imaging ModeContinuous Wave Doppler
    ApplicationHospital, Clinical
    MeasurementsCardio, Vascular
    BrandVERSALAB
    Frequency8, 5, 4
    Waveform ModeSpectrum
    Speaker Output300

    Our PC Based Vascular Doppler Recorder VERSALAB series supplied in two versions. It is designed to produce Ankle Brachial Index (ABI), Toe Brachial Index (TBI), Doppler Velocity Waveform. Arterial and Venous examinations are very much possible. It can assist in the determination of prognosis of ulcer healing by using PPG and is used for studying penile dysfunction. It comes with PC software for printouts and can be connected to any computer.

    VERSALAB LE: Semi-automated ABI and TBI measurement
    VERSALAB Auto: Fully automated ABI, TBI measurement, Upper & Lower Extremity Study, Carotid Exams and Penile arterial examinations are standard feature.

    Features:
    •  8MHz Uni-directional Vascular Doppler probe
    • Toe PPG Toe sensor
    • Segmental BP cuffs
    • Computer Interface through USB
    • Colorful reports


    Additional Information:

    • Item Code: Versalab-Dx
    • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
    • Port of Dispatch: Chennai
    • Production Capacity: 100 per month
    • Delivery Time: 1 week
    • Packaging Details: As per customer requirement
    Send Business Enquiry

    View PDF

    ABI Arterial Doppler Recorder

    REQUEST CALLBACK

    ABI Arterial Doppler Recorder
    Ask for Price

    Thanks for Contacting Us.

    Product Price :Get Latest Price

    Product Details:
    Minimum Order Quantity1 Piece
    Doppler Probe8MHz Uni-directional probe
    Toe ProbeAccurate PPG Toe Sensor
    Power100 Volts to 250 Volts operation
    ApplicationArterial,Venous,Carotid and Penile study

    Our esteemed clients are presented ABI Arterial Doppler Recorder from our wide gamut of Vascular Doppler Recorder Products. It is extensively used for manual ankle brachial index study apart from PPG for toe pressure measurement. It allows monitoring and recording of velocity as well as pulse volume waveforms apart from penile flow study. It also features PC software for storing and printing the data. It can be availed at reasonable prices.

    Features:

    • 8MHz Uni-directional Doppler
    • PPG Toe Sensor
    • Ankle Brachial Index (ABI)
    • Toe Brachial Index (TBI)
    • Doppler Velocity Waveform
    • Arterial Doppler
    • Arterial and Vascular Examination
    • BP cuffs for ABI/TBI
    • Penile Doppler Study
    • Computer Connectivity 
    • USB Connection
    • Software to connect computer and Unit
    • Software helps to store data 
    • Software produces patient reports


    Additional Information:

    • Item Code: VERSALAB
    • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
    • Port of Dispatch: Chennai, INDIA
    • Production Capacity: 250 units per month
    • Delivery Time: Immediate
    • Packaging Details: As per Customer Requirement.
    Send Business Enquiry

    View PDF
     
    X


    Explore More Products

    Contact via E-mail
    Contact via SMS
    Diabetik Foot Care India Pvt Limited
    Elango Devy (Managing Director)
    No. 18/1, Kannappa Nagar 3rd Main Road, Thiruvanmiyur,
    Chennai - 600041, Tamil Nadu, India
    Call Us: 
    Call Response Rate: 92%
    Share Us :
    F G T L



    Home  |   Profile   |  Product Range  |  Site Map  |   Contact Us

    © Diabetik Foot Care India Pvt Limited. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited

    Diabetik Foot Care India Pvt Limited