Diabetik Foot Care India Pvt Limited
Diabetik Foot Care India Pvt Limited
Send Email
0804895454691% Response Rate
Search

Home » Product Range


Medical Electronic Equipment

We are a well-known manufacturer, distributor, wholesaler and exporter of complete range of medical equipments specialising in diabetic foot management. These equipment have been manufactured as per strict quality control parameters, using premium grade raw-material and components.

 

All the machines and instruments offered by us are available at reasonable prices and are known for their accurate results. These are used widely all across the globe in a number of medical and therapeutic applications.

 

We offer the following:



Neuropathy Screening and Detection EquipmentsGet Quotation

One of the frequent causes of non-traumatic lower-limb amputation is Diabetes and is usually preceded by foot ulcer and infection. The reason of this ulceration is commonly a loss of protective sensation due to peripheral neuropathy, for which there is no prevention strategy. Current research promotes early detection of neuropathy so that secondary prevention measures, such as intensive foot-care education and treatment, can be used for individuals.

Since diabetic neuropathy involves the nerves, the neurological exam is a crucial part of the diagnosis. Different nerves are in charge of transmitting different sensory messages, such as temperature, touch, and vibration. Damaged nerves can’t transmit messages as well as they should, so these tests can be very helpful in narrowing down which nerves are affected.

 Some possible sensation tests are:
  • Temperature: (Hot / Cold)
  • Touch: Monofilament 10gm
  • Vibration: Digital Biothesiometer

 

Send Business Enquiry




Digital BiothesiometerGet Quotation
Diabetes is the leading cause of neuropathy in developed countries, and neuropathy is the most common complication and greatest source of morbidity and mortality in diabetes patients. It is estimated that the prevalence of neuropathy in diabetes patients is approximately 20%. Diabetic neuropathy is implicated in 50-75% of nontraumatic amputations.

Uncontrolled diabetes leads to lots of complications in diabetic neuropathy patients. Diabetic neuropathies are a family of nerve disorders caused by diabetes. People with diabetes can, over time, develop nerve damage throughout the body. Some people with nerve damage have no symptoms. About 60 to 70 percent of people with diabetes have some form of neuropathy. People with diabetes can develop nerve problems at any time, but risk rises with age and longer duration of diabetes.

Our ranges of Neuropathy Products helps to quantitate the diabetic neuropathy. All these Diabetic Neuropathy Products are thoroughly tested by team of talented professionals, thus ensuring 100% precise result. Today, we have carved a niche as one of the major Neuropathy Care Products Exporters from India. Our Digital Biothesiometer are exported to as many as 34 countries.

Send Business Enquiry




Vascular Doppler ProductsGet Quotation
A Closer Look At Non-Invasive Testing Methods For PAD

Whenever one suspects Peripheral Arterial Disease (PAD), the clinician must perform  the five non-invasive vascular testing methods that are commercially available and widely implemented.  The instruments used for measuring ABI are described under this section.

Ankle Brachial Index:

The ankle brachial index is the most well-known, non-invasive vascular testing tool. ABI test is performed with a Doppler and a blood pressure cuff. One calculates the ABI by dividing the ankle pressure by the brachial systolic pressure. An ABI of <0.9 is abnormal and  ABI values have a linear correlation with wound healing potential in lower extremity wounds.   Patients with DM may have calcified and hardened lower extremity arterial walls that cannot be readily compressed and occluded with blood pressure cuffs. This produces falsely elevated ankle pressure readings that are often in the “normal ABI range” (0.9 to 1.2) or sometimes in the non-physiological range of above 1.3. 
 
Pros.: The ABI is a relatively quick and cost-effective test for screening of PAD with known sensitivity and specificity of 90 percent or higher.  

Cons.: Calcified leg arteries in DM or dialysis patients may yield falsely elevated ABI results.  


Send Business Enquiry




Vascular Doppler Recorder ProductsGet Quotation
A Closer Look At Non-Invasive Testing Methods For PAD

Whenever one suspects Peripheral Arterial Disease (PAD), the clinician must perform  the five non-invasive vascular testing methods that are commercially available and widely implemented. They include the ankle brachial index ABI), the toe-brachial index(TBI), pulse volume recording(PVR), transcutaneous oxygen monitoring(TCPO2) and skin perfusion pressure(SPP).

Ankle Brachial Index:

The ankle brachial index is the most well-known, non-invasive vascular testing tool. ABI test is performed with a Doppler and a blood pressure cuff. One calculates the ABI by dividing the ankle pressure by the brachial systolic pressure. An ABI of <0.9 is abnormal and  ABI values have a linear correlation with wound healing potential in lower extremity wounds.   Patients with DM may have calcified and hardened lower extremity arterial walls that cannot be readily compressed and occluded with blood pressure cuffs. This produces falsely elevated ankle pressure readings that are often in the “normal ABI range” (0.9 to 1.2) or sometimes in the non-physiological range of above 1.3. 
 
Pros.: The ABI is a relatively quick and cost-effective test for screening of PAD with known sensitivity and specificity of 90 percent or higher.  

Cons.: Calcified leg arteries in DM or dialysis patients may yield falsely elevated ABI results.  

Toe-Brachial Index:


One would calculate TBI by dividing the blood pressure of the great toe by the systolic brachial blood pressure. Toe pressure of > 50mmHg is considered normal. Toe pressure < 30 mmHg is considered severely ischemic.

Pros.:
 The digital arteries in great toes are considered to be less affected by medial arterial calcification.

Cons.: There are site limitations such as the inability to measure toe pressure due to toe wounds or toe amputation.

Send Business Enquiry




Plantar Pressure EquipmentsGet Quotation

Early identification of feet 'at risk' for ulceration is important in preventing plantar lesions in diabetic patients with insensitive feet. Plantar pressures are higher in diabetic neuropathic patients than non-diabetic and non-neuropathic Counterparts. As high plantar pressure is a proven risk factor for foot ulceration, effective screening for high plantar pressures in diabetic patients could have a major influence on the incidence of diabetic foot ulceration. 

Send Business Enquiry




Foot Care ProductsGet Quotation
Our product range includes a wide range of semi automatic plantar pressure foot scan podiascan, portable diabetic foot neuropathy testing digital biothesiometer and 120hz diabetic foot digital biothesiometer.

Send Business Enquiry




Wound Care & Therapy EquipmentsGet Quotation
We offer our Client's with complete range of wound care and therapy Products & solution.

The range of products include -

* IR LED Light Therapy - Neurolite
* Neuromuscular Stimulator - Neurostim 
* TENS
* Ultrasound Wound Debrider
* Wound Measurement Camera - WZ20
* TCOM monitor 

Send Business Enquiry




Foot Care ProductGet Quotation
Our product range includes a wide range of monofilaments 10 gm and professional electric nail file pedicure kit.

Send Business Enquiry




Neuropathy Treatment ProductsGet Quotation
Leading Manufacturer of neuropathy therapy stimulator hospital model from Chennai.

Send Business Enquiry




Podiatry EquipmentsGet Quotation
We have high quality podiatry chairs and podiatry instruments.

Podiatry chairs are supplied with 3 motor and 5 motor models and they are made for long life.


Our Podiatry Kits are exported to many countries.

We supply a full Podiatry Kit containing 10 different useful tools and also a moni Podiatry kit with 5 essential tools for the management of podiatry procedures.

These tools are made of strong stainless steel material to work for a longer duration.

Send Business Enquiry




TCOM MonitorGet Quotation
  • The transcutaneous oxygen measurement unit Precise Range of tcpO2 are intended for the measurement partial pressure of oxygen, also known as tcpO2, on the surface of the skin.

    The probe parameters, the measurement process, as well as the tcpO2 measurement results of three measurements can be saved onto the internal memory.

    Area of Applications:

    • Wound healing process (diagnosis & prediction). 
    • Chronic venous insufficiency and ischemia. 
    • Confirmation of diagnosis and blood gas monitoring. 
    • Measurement for individual amputation level. 
    • Fitting of prostheses. 
    • Diabetes & peripheral artery disease PAD. 
    • Diagnostics in vascular ischemia. 
    • Plastical surgery diagnostics.  

Send Business Enquiry




Stainless Steel Door KitGet Quotation
Manufacturer of a wide range of products which include stainless steel podiatry kit mini for professional and professional full podiatry kit.

Send Business Enquiry




 


Contact via E-mail
Contact via SMS
Elango Devy (Managing Director)
Diabetik Foot Care India Pvt Limited
No. 18/1, Kannappa Nagar,3rd Main Road, Thiruvanmiyur
Chennai - 600041, Tamil Nadu, India
Call Us: 
Call Response Rate: 91%
Share Us :



Home  |   About Us   |  Product Range  |  Site Map  |   Contact Us

© Diabetik Foot Care India Pvt Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Diabetik Foot Care India Pvt Limited