Diabetik Foot Care India Pvt Limited
Diabetik Foot Care India Pvt Limited
Send Email
0804895454693% Response Rate
Search

Home » Product Range » Vascular Doppler Recorder Products


Vascular Doppler Recorder Products

A Closer Look At Non-Invasive Testing Methods For PAD

Whenever one suspects Peripheral Arterial Disease (PAD), the clinician must perform  the five non-invasive vascular testing methods that are commercially available and widely implemented. They include the ankle brachial index ABI), the toe-brachial index(TBI), pulse volume recording(PVR), transcutaneous oxygen monitoring(TCPO2) and skin perfusion pressure(SPP).

Ankle Brachial Index:

The ankle brachial index is the most well-known, non-invasive vascular testing tool. ABI test is performed with a Doppler and a blood pressure cuff. One calculates the ABI by dividing the ankle pressure by the brachial systolic pressure. An ABI of <0.9 is abnormal and  ABI values have a linear correlation with wound healing potential in lower extremity wounds.   Patients with DM may have calcified and hardened lower extremity arterial walls that cannot be readily compressed and occluded with blood pressure cuffs. This produces falsely elevated ankle pressure readings that are often in the “normal ABI range” (0.9 to 1.2) or sometimes in the non-physiological range of above 1.3. 
 
Pros.: The ABI is a relatively quick and cost-effective test for screening of PAD with known sensitivity and specificity of 90 percent or higher.  

Cons.: Calcified leg arteries in DM or dialysis patients may yield falsely elevated ABI results.  

Toe-Brachial Index:


One would calculate TBI by dividing the blood pressure of the great toe by the systolic brachial blood pressure. Toe pressure of > 50mmHg is considered normal. Toe pressure < 30 mmHg is considered severely ischemic.

Pros.:
 The digital arteries in great toes are considered to be less affected by medial arterial calcification.

Cons.: There are site limitations such as the inability to measure toe pressure due to toe wounds or toe amputation.

Versalab Automated Vascular Doppler Recorder for ABI TBI

REQUEST CALLBACK

Versalab Automated Vascular Doppler Recorder for ABI TBI
  • Versalab Automated Vascular Doppler Recorder for ABI TBI
  • Versalab Automated Vascular Doppler Recorder for ABI TBI
  • Versalab Automated Vascular Doppler Recorder for ABI TBI
  • +10 Versalab Automated Vascular Doppler Recorder for ABI TBI
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2.9 Lakh / PieceGet Latest Price

Product Brochure
Product Details:
Model Name/NumberVersalab Auto
Audio Output Power8W
Display Area320x128 display
Usage/ApplicationVascular Screening
Frequency5 MHz, 8 MHz
Waveform ModeSpectrum
Speaker Output300 mW
ApplicationClinical
Is It PortablePortable
ConnectivityConnectivity
BrandVersalab
Weight8 (Kg)
Number Of Transducer Sockets5
Power Consumption40watt

The Versalab Automated Vascular Doppler Recorder for ABI TBI is a measure of the severity of atherosclerosis in the legs but is also an independent indicator of the risk of subsequent atherothrombotic events elsewhere in the vascular system. The ABI may be used as a risk marker both in the general population free of clinical CVD and in patients with established CVD.

Continuous wave Vascular Doppler ultrasound is considered a reliable tool and was validated and accepted into routine medical practice. The literature recognises the importance of assessment in the management of a patient with chronic lower limb ulceration. The evidence from the medical literature indicates that a "normal" ABI is 0.91 or greater, a ratio below this indicating arterial disease.

Patients with DM may have calcified and hardened lower extremity arterial walls that cannot be readily compressed and occluded with blood pressure cuffs. This produces falsely elevated ankle pressure readings that are often in the “normal ABI range” (0.91 to 1.4) or sometimes in the non-physiological range of above 1.4. However, Calcified leg arteries in Diabetes Mellitus or dialysis patients may yield falsely elevated ABI results.

Pulse volume recording, also known as air Plethysmography, is a noninvasive test that measures blood flow within the blood vessels or arteries. The first sign of possible abnormality is the absence of the dicrotic notch. More significant occlusions will show a decreased slope of the ascending and descending segments and a rounding of the systolic peak. More serious obstructions will show flattened waveforms.

Versalab Auto is capable of conducting ABI, TBI, PVR, Segmental Doppler, Upper Extremity Exam, Carotid and Penile Doppler studies. The blood pressure for the above measurements are done by a built-in mechanism and the BP measurement are validated by the software and helps the user to correct the BP measurement incase of any patient artifact. This quality control method helps to detect the systolic BP accurately.

Features:
  • Automated Ankle Brachial Index and Toe Brachial Index
  • Doppler (C.W) with 8MHz Transducer
  • Photo Plethysmography (PPG) Toe sensor
  • Large LCD screen to display parameter
  • Silent pump measures the systolic BP
  • Segmental cuff sets with toe cuff
  • Penile flow study
  • Software for complete arterial vascular profile
  • Computer connectivity enabled
  • Software for data transfer, storage and patient report
  • Software supports Windows Xp(SP3)/ Win 7/ Win 8/ Win10
  • Standards matching International standards


Additional Information:

  • Item Code: VERSALAB-Auto
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Chennai, India
  • Production Capacity: 100 per month
  • Delivery Time: Immediate
  • Packaging Details: As per customer requirement
Send Business Enquiry

Automatic Ankle Brachial Index Vascular Doppler Recorder

REQUEST CALLBACK

Automatic Ankle Brachial Index Vascular Doppler Recorder
  • Automatic Ankle Brachial Index Vascular Doppler Recorder
  • Automatic Ankle Brachial Index Vascular Doppler Recorder
  • Automatic Ankle Brachial Index Vascular Doppler Recorder
  • +6 Automatic Ankle Brachial Index Vascular Doppler Recorder
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 3.25 Lakh / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 Piece
Model Name/NumberVASOCHEK+
Audio Output Power8W
Display Area320x128 LCD display
Machine ConditionNew
Usage/ApplicationVascular Screening including Arterial and Venous arteries.
ApplicationClinical, Hospital
BrandDFCIndia
Doppler ModeContinuous Wave
Frequency5 MHz, 4 MHz, 8 MHz
Probe8MHz
Waveform ModeSpectrum
MeasurementsVascular
Speaker Output200 mW
Is It PortablePortable
ConnectivityConnectivity
Weight8 (Kg)
Battery BackupNo
Number Of Transducer Sockets2
Display TypeGraphic LCD
Built-In FuseYes
Power Consumption60 W
Country of OriginMade in India

Our PC Based Vascular Doppler Recorder Versalab series supplied in two versions. It is designed to produce Ankle Brachial Index (ABI), Toe Brachial Index (TBI), Doppler Velocity Waveform. Arterial and Venous examinations are very much possible. It can assist in the determination of prognosis of ulcer healing by using PPG and is used for studying penile dysfunction. It comes with PC software for printouts and can be connected to any computer.

Versalab Le: Semi-automated ABI and TBI measurement

Versalab Auto:
Fully automated ABI, TBI measurement, Upper & Lower Extremity Study, Carotid Exams and Penile arterial examinations are standard feature.

Features:

  • 8MHz Uni-directional Vascular Doppler probe
  • Toe PPG Toe sensor
  • Segmental BP cuffs
  • Computer Interface through USB
  • Colorful reports


Additional Information:

  • Item Code: Versalab-Dx
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Chennai
  • Production Capacity: 100 per month
  • Delivery Time: 1 week
  • Packaging Details: As per customer requirement
Send Business Enquiry

Abi Tbi Arterial Doppler Recorder for Hospital

REQUEST CALLBACK

Abi Tbi Arterial Doppler Recorder for Hospital
  • Abi Tbi Arterial Doppler Recorder for Hospital
  • Abi Tbi Arterial Doppler Recorder for Hospital
  • Abi Tbi Arterial Doppler Recorder for Hospital
  • +1 Abi Tbi Arterial Doppler Recorder for Hospital
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2 Lakh / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 Piece
Model Name/NumberVASOCHEK+
Machine ConditionNew
ApplicationHospital,Clinical, Hospital, Clinical
BrandDFCIndia
Frequency4 MHz, 8 MHz, 5 MHz
Doppler ModeContinuous Wave
Waveform ModeSpectrum
Speaker Output300 mW
Warranty1 Year
Is It PortablePortable
Battery BackupNo
Country of OriginMade in India
Dimensions295mm(L) x 320mm(D) x 175mm(H)
Weight with accessories8.50Kg
Instrument Weight4.25Kg

We are engaged in supplying TBI Arterial Doppler Recorder from our premium collection of Vascular Doppler Recorder Products. It is designed for manual toe brachial index study and PPG for toe pressure measurement. It also facilitates penile flow study and monitoring and recording of velocity as well as pulse volume waveforms. It is provided with PC software for storing and printing of data and can be availed at competitive rates.

Features:
  • 8 MHz unidirectional doppler transducer
  • Manual ankle brachial index study
  • Photo plethysmography (PPG) for toe pressure measurement
  • Monitoring & Recording of velocity & pulse volume waveforms
  • Segmental cuffsets with Toe cuff for AB Index and TB Index
  • Penile flow study
  • PC software for storage and printout on A4 size plain paper
  • Gets connected on to any computer(computer not included) through RS232 serial port
  • USB Port connection is an option
  • Light weight and portable





Additional Information:

  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Chennai, INDIA
  • Production Capacity: 250 units per month
  • Delivery Time: Immediate
  • Packaging Details: As per Customer Requirement
Send Business Enquiry

Semi-automated Vascular Doppler Recorder for ABI and TBI

REQUEST CALLBACK

Semi-automated Vascular Doppler Recorder for ABI and TBI
  • Semi-automated Vascular Doppler Recorder for ABI and TBI
  • Semi-automated Vascular Doppler Recorder for ABI and TBI
  • Semi-automated Vascular Doppler Recorder for ABI and TBI
  • Semi-automated Vascular Doppler Recorder for ABI and TBI
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2 Lakh / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 Piece
Model Name/NumberVASOCHEK+
Machine ConditionNew
Imaging Mode2D
Instrument TypeBench-top
Frequency5 MHz, 8 MHz
Waveform ModeSpectrum
Warranty1 Year
Speaker Output300 mW
Is It PortablePortable
ApplicationClinical
BrandDFCIndia
ConnectivityConnectivity
Weight5 Kg
Battery BackupNo
Number Of Transducer Sockets2
Country of OriginMade in India

The Vasochek+ is a semi-automated Vascular Doppler Recorder for ABI / TBI is a measure of the severity of atherosclerosis in the legs but is also an independent indicator of the risk of subsequent atherothrombotic events elsewhere in the vascular system. The ABI may be used as a risk marker both in the general population free of clinical CVD and in patients with established CVD.

Continuous wave Doppler ultrasound is considered a reliable tool and was validated and accepted into routine medical practice. The literature recognises the importance of assessment in the management of a patient with chronic lower limb ulceration. The evidence from the medical literature indicates that a "normal" ABI is 0.91 or greater, a ratio below this indicating arterial disease.

Patients with DM may have calcified and hardened lower extremity arterial walls that cannot be readily compressed and occluded with blood pressure cuffs. This produces falsely elevated ankle pressure readings that are often in the “normal ABI range” (0.91 to 1.4) or sometimes in the non-physiological range of above 1.4. However, Calcified leg arteries in Diabetes Mellitus or dialysis patients may yield falsely elevated ABI results.

A photoplethysmogram (PPG) is an optically obtained Plethysmogram, a volumetric measurement of an organ. The PPG Toe blood pressure and related Toe Brachial Index (TBI) are performed to assess the vascular condition of the foot by obtaining systolic pressures at the toe. Toe pressures may be useful in cases of unsuspected vascular disease and in baseline diabetic foot assessment where falsely high ankle pressures can occur due to calcification of tibial vessel.

Features:
  • Ankle Brachial Index and Toe Brachial Index
  • Doppler (C.W) with 8MHz Transducer
  • Photo Plethysmography (PPG) Toe sensor
  • Large LCD screen to display parameter
  • Software for complete arterial vascular profile
  • Computer connectivity enabled
  • Software for data transfer, storage and patient report
  • Software supports Windows Xp(SP3)/ Win 7/ Win 8/ Win10
  • Standards matching International standards


Additional Information:

  • Item Code: VASOCHEK
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Chennai, India
  • Production Capacity: 100 per month
  • Delivery Time: Immediate
  • Packaging Details: As per customer requirement
Send Business Enquiry

Semi-automated Vascular Doppler Recorder for ABI and TBI

REQUEST CALLBACK

Semi-automated Vascular Doppler Recorder for ABI and TBI
  • Semi-automated Vascular Doppler Recorder for ABI and TBI
  • Semi-automated Vascular Doppler Recorder for ABI and TBI
  • Semi-automated Vascular Doppler Recorder for ABI and TBI
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2 Lakh / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 Piece
Model Name/NumberVASOCHEK+
Machine ConditionNew
Doppler ModeContinuous Wave
Frequency8 Mhz
Warranty1 Year
Is It PortablePortable
BrandDFCIndia
Weight10 (Kg)
Battery BackupNo
Voltage100-250 V
Country of OriginMade in India
Dimensions295mm(L) x 320mm(D) x 175mm(H)
Instrument Weight4.25Kg
Weight with accessories8.50Kg

Our esteemed clients are presented  Semi-automated  Vascular Doppler Recorder model VASOCHEK+  from our wide gamut of Vascular Doppler Recorder Products. It is extensively used for manual ankle brachial index study apart from PPG for toe pressure measurement. It allows monitoring and recording of velocity as well as pulse volume waveforms apart from penile flow study. It also features PC software for storing and printing the data. It can be availed at reasonable prices.

Features:
  • 8MHz Uni-directional Doppler
  • PPG Toe Sensor
  • Ankle Brachial Index (ABI)
  • Toe Brachial Index (TBI)
  • Doppler Velocity Waveform
  • Arterial Doppler
  • Arterial and Vascular Examination
  • BP cuffs for ABI/TBI
  • Penile Doppler Study
  • Computer Connectivity
  • USB Connection
  • Software to connect computer and Unit
  • Software helps to store data
  • Software produces patient reports


Additional Information:

  • Item Code: VERSALAB
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Chennai, INDIA
  • Production Capacity: 250 units per month
  • Delivery Time: Immediate
  • Packaging Details: As per Customer Requirement.
Send Business Enquiry

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Elango Devy (Managing Director)
Diabetik Foot Care India Pvt Limited
No. 18/1, Kannappa Nagar,3rd Main Road, Thiruvanmiyur
Chennai - 600041, Tamil Nadu, India
Call Us: 
Call Response Rate: 93%
Share Us :



Home  |   About Us   |  Product Range  |  Site Map  |   Contact Us

© Diabetik Foot Care India Pvt Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Diabetik Foot Care India Pvt Limited